Item type:Publication, Structural and optical properties of mixed phase WO3 – ZnWO4 films synthesized from thermally oxidized metallic Zn–W films(Elsevier BV, 2026-06) ;Jovanovski, Stefan ;Popović, Maja ;Novaković, MirjanaTungsten-bearing compounds have attracted significant interest in recent years, especially in thin films or nano powder form, due to their photocatalytic activity stemming from their wide band gap semiconductor properties. This study presents the synthesis of mixed phase WO3–ZnWO4 films synthesized by thermal oxidation of co-sputtered metallic Zn–W films. From XRD analysis it appeared that annealing at 600 °C leads to the formation of the monoclinic Zn-tungstate phase within the WO3 matrix with crystallite size about 50 nm for both phases. The XPS analysis of the O1s peak showed mixed phase compound of WO3 matrix with about 13 at.% of ZnWO4. Raman and infrared spectroscopy further characterize the structural features, revealing the WO6 octahedral unit as main building block in the structure. The optical band gap of the annealed film was found to be 3.34 eV, indicating a wide gap semiconductor. The films displayed a UV induced Photoluminescence with broad PL spectra with emission maximum at about 2.48 eV. The study demonstrates that co-sputtering and annealing at 600 °C approach is effective for synthesizing of tungstate phase ZnWO4 within WO3 matrix. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Diagnostic reference levels (DRLs) in digital mammography in the European context – a systematic review(Walter de Gruyter GmbH, 2025-08-28) ;Arifi, Mirjeta MedijiRistova, Mimoza M.This systematic review examines the establishment of Diagnostic Reference Levels (DRLs) in digital mammography across 18 European countries, based on studies from 2005-2025. A total of 353 articles were identified through the comprehensive search of academic networks: Google Scholar, PubMed, Research Gate, Academia. Only 18 peer-reviewed studies met inclusion criteria – reporting Mean Glandular Dose (MGD)-based DRLs from Finland to Malta. Eight studies used patient data, four used phantom measurements, and six used both. To overcome the challenging comparison of the variety of reported parameters, we undertook some data harmonisation procedures, focusing on a common Compressed Breast Thickness (CBT) range of 50-59 mm. The DRLs varied notably by country, with 75th percentile MGDs ranging from 1.1 to 2.6 mGy and 95th percentile from 1.6 to 2.9 mGy, averaging to 1.44 mGy, which is lower than the achievable European level (2 mGy). The harmonisation approach enabled the derivation of a comparable dataset of average MGDs, facilitating cross-country comparisons and insights into radiation dose optimisation in digital mammography across Europe. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Preparation of CuWO4 films by thermal annealing of simultaneously RF/DC magnetron co-sputtered Cu–W films(Elsevier BV, 2025-10) ;Jovanovski, Stefan ;Popović, Maja ;Novaković, Mirjana ;Jugović, DraganaGloginjić, Marko - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Structural, optical, and photoluminescence properties of CdWO4 films synthesized by a chemical bath deposition method(Walter de Gruyter GmbH, 2025-03-01) ;Jovanovski, Stefan - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Breast Glandularity Distribution and Refining the Mean Glandular Dose Estimates in Digital Mammography(Ovid Technologies (Wolters Kluwer Health), 2025-10) ;Arifi, Mirjeta MedijiBackground: In mammography, radiation dose is typically expressed as the mean glandular dose (MGD), which represents the dose delivered to the glandular tissue of the breast. Materials and Methods: This study compares MGD estimates obtained using three different methodologies: (I) MGD-Dance-Laboratory for Individualized Breast Radiodensity Assessment (LIBRA) – Calculated manually for each patient using Dance’s formula, incorporating mammographic breast density values derived from the LIBRA application, thereby replacing Dance’s standard glandularity assumption with image-specific values; (II) MGD-Dance – Calculated using Dance’s formula with the conventional assumption of 50% glandularity; (III) MGD-Displayed – Extracted directly from the Digital Imaging and Communication in Medicine header of each mammogram. Results: A total of 688 anonymized mammograms from 172 women undergoing routine screening were analyzed, with complete technical and patient-related data. The mean MGD values obtained by the three methods were: MGD-Dance-LIBRA: 2.97 mGy; MGD-Dance: 2.78 mGy; and MGD-Displayed: 2.81 mGy. The average glandularity across the dataset was estimated at 14%. A strong correlation was observed between MGD-Dance and MGD-Dance-LIBRA values (R² =0.9865). The refined dose estimation using image-specific glandularity from LIBRA consistently produced slightly higher values compared to the standard Dance method, highlighting the impact of the commonly assumed 50% glandularity, which overestimates the true average density. Conclusions: Incorporating individualized breast density estimates from the LIBRA application into Dance’s formula provides a more refined and accurate method for calculating MGD in digital mammography. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Establishing Diagnostic Reference Levels in Digital Mammography from Eight Mammography Units Using over 30,000 Images(MDPI AG, 2025-03-10) ;Mediji-Arifi, MirjetaIntroduction: Diagnostic reference levels (DRLs) in digital mammography were determined from 31,040 digital mammography images acquired from diagnostic and screening examination data from eight state-managed mammography centers/units in the Republic of North Macedonia (RM). The main objective is to establish a diagnostic reference level for mammography examinations at different ranges of breast thickness. Materials and methods: Approximately 30,000 mammography images were used to evaluate mean glandular dose (MGD) and compressed breast thickness (CBT) for each projection, craniocaudal (CC) and mediolateral oblique (MLO). The stratified DRL was derived by calculating the 75th percentile of the MGD across all the samples at various CBT ranges for both projections. Results and Discussion: The overall median MGDs, minimum, and maximum were calculated to be 1.15 mGy, 0.1 mGy, and 9.93 mGy, respectively. As the CBT increased from 7 to 120 mm, the 75th percentile of the MGD increased from 0.94 mGy to 3.67 mGy for CC, and from 0.44 mGy to 4.91 mGy for MLO projections. Conclusions: The study established local DRLs for the digital mammography systems at the 75th percentile, which compared well with the values reported for other countries/regions. The DRL defined per CC and MLO image view for a specific CBT indicated that at least one mammography facility needs optimization. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Formation of WO3 thin films from RF sputtered tungsten films by air annealing: A cost-effective approach(National Library of Serbia, 2025) ;Jovanovski, Stefan ;Popovic, Maja ;Novakovic, Mirjana ;Rajic, VladimirWO3 thin films were prepared by RF sputtering metallic tungsten onto glass substrates, followed by thermal oxidation through annealing in air. This technique is straightforward, cost-efficient, and time-effective, achieving high deposition rates of 16 nm/min on average at 200 W magnetron power for the highly homogeneous W-metallic films. SEM/EDX analysis showed that after annealing at 450ᵒC in air, the RF sputtered 269 nm thick metallic W films with a round grain morphology (~30 nm) turned into 420 nm thick nearly stoichiometric transparent WO3 (tungsten (VI) oxide) film, with a dramatically changed morphology of aggregated crystal rods approximately 1 μm long. XRD and Raman spectroscopy confirmed a biphasic crystal structure, with a dominant monoclinic phase and a minor tetragonal phase. XPS analysis revealed the characteristic W4f7/2 and W4f5/2 electron peaks associated with the W6+ oxidation state, with no evidence of W5+ species, indicating a stoichiometric nature of the WO3 films. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Models of care and associated targeted implementation strategies for cancer survivorship support in Europe: a scoping review protocol(BMJ, 2025-02) ;Prue, Gillian ;Czamanski-Cohen, Johanna ;Kassianos, Angelos P ;Pilleron, SophieLadas, AristeaIntroduction Cancer and its treatments can lead to a wide range of side-effects that can persist long after treatments have ended. Across Europe, survivorship care is traditionally hospital-based specialist-led follow-up, leading to gaps in supportive care. Improved screening, diagnosis and treatment increase survival rates. With more individuals living with, through and beyond cancer, the predominance of the hospital-based specialist model is unsustainable, costly and resource-intensive. An understanding of what alternative Models of Care are available and the barriers and facilitators to their implementation is a first step towards enhancing supportive care across the cancer journey. The aim of this scoping review is to source and synthesise information from studies evaluating patient-oriented models of cancer survivorship supportive care for adults in Europe. Methods and analysis The scoping review will be reported in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses—Scoping Review Extension guidelines and will be guided by a six-stage methodological framework. A search strategy has been developed according to the Population, Concept and Context structure and will be applied to seven databases. A targeted search of grey literature will be completed. All identified records will be screened using predefined eligibility criteria by at least two researchers and undergo full-text review for inclusion. Data pertaining to the conceptualisation, evaluation and implementation of sourced Models of Care will be extracted. Ethics and dissemination As there is no primary data, ethical approval is not required. This review will be conducted as part of the EU COST Action CA21152—Implementation Network Europe for Cancer Survivorship Care. The protocol and subsequent scoping review will be published in a peer-reviewed journal. The Action involves representatives from most countries across Europe which will assist with the dissemination of the work to key stakeholders. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Impedance and AC Conductivity of GdCr1−xCoxO3 ( x = 0, 0.33, 0.5, 0.67 and 1) Perovskites(Wiley, 2014-09) ;Pecovska‐Gjorgjevich, Margareta; ;Marinšek, Marjan; Jo, W. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Electrical properties and conductivity mechanism for Ca2KH7(PO4)4·2H2O and Ca2(NH4)H7(PO4)4·2H2O(Elsevier BV, 2025-12) ;Najkov, K. ;Koleva, V. ;Stefov, V.Pecovska Gjorgjevich, M.