Ве молиме користете го овој идентификатор да го цитирате или поврзете овој запис: http://hdl.handle.net/20.500.12188/33432
DC FieldValueLanguage
dc.contributor.authorJankulovska, Mirjana S.en_US
dc.contributor.authorJosimovska, Teodoraen_US
dc.contributor.authorVelkoska-Markovska, Lencheen_US
dc.date.accessioned2025-05-07T09:10:49Z-
dc.date.available2025-05-07T09:10:49Z-
dc.date.issued2024-09-30-
dc.identifier.urihttp://hdl.handle.net/20.500.12188/33432-
dc.description.abstractArtificial sweeteners are low-calorie substances used as food additives with aim to impart a sweet taste to beverages without adding significant calories. Due to the regulatory compliance regarding the type and the amount of artificial sweetener, and due to the large consumption of beverages and the effects of artificial sweeteners on human health, their identification and quantification is of a great importance. In this research simultaneous determination of acesulfame K (ACE-K), sodium saccharin (Na-SAC) and aspartame (ASP) as the most commonly used sweeteners in beverages was performed with a reversed – phase high performance liquid chromatography (RP – HPLC) with diode array detection (DAD). The best separation of the analytes was achieved on a Poroshell 120 EC-C18 (3.0 3 50 mm, 2.7 μm) column and isocratic elution with a mobile phase consisted of acetonitrile and diluted phosphoric acid (pH 5 3.8) with 7/93 volume ratio (V/V), and flow rate of 1 mL min 1. The chromatographic process was followed at 195, 220 and 230 nm, under constant column temperature (25 8C). Under these chromatographic conditions, the total time of analysis was less than 5 min. The developed method was validated for linearity, precision, accuracy, limit of detection (LOD) and limit of quantification (LOQ). The LOD under established chromatographic conditions was 0.03, 0.07 and 0.17 mg L 1 for Na-SAC, ACE-K and ASP, respectively. The amount of artificial sweeteners in analyzed samples ranged from 30.32 to 148.37 mg L 1 for ACE-K, from 16.10 to 93.05 for Na-SAC, and from 6.06 to 512.72 for ASP. The validated method was successfully applied for determination of analytes in different commercially available beverages.en_US
dc.language.isoenen_US
dc.publisherAkademiai Kiado Zrt.en_US
dc.relationThis research was a part of the project “Development and validation of an analytical method for the simultaneous determination of preservatives, sweeteners and caffeine in beverages” funded by Ministry of education and science of North Macedonia.en_US
dc.relation.ispartofActa Chromatographicaen_US
dc.subjectacesulfame K, sodium saccharin, aspartame, beverages, RP-HPLCen_US
dc.titleDevelopment and validation of RP-HPLC method with UV-DAD detection for simultaneous determination of acesulfame K, sodium saccharin and aspartame in beveragesen_US
dc.typeArticleen_US
dc.identifier.doi10.1556/1326.2024.01239-
dc.identifier.urlhttps://akjournals.com/view/journals/1326/aop/article-10.1556-1326.2024.01239/article-10.1556-1326.2024.01239.xml-
dc.identifier.urlhttps://akjournals.com/downloadpdf/journals/1326/aop/article-10.1556-1326.2024.01239/article-10.1556-1326.2024.01239.xml-
dc.identifier.urlhttps://akjournals.com/downloadpdf/journals/1326/aop/article-10.1556-1326.2024.01239/article-10.1556-1326.2024.01239.xml-
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:Faculty of Agricultural Sciences and Food: Journal Articles
Files in This Item:
File SizeFormat 
online published.pdf850.87 kBAdobe PDFView/Open
Прикажи едноставен запис

Google ScholarTM

Проверете

Altmetric


Записите во DSpace се заштитени со авторски права, со сите права задржани, освен ако не е поинаку наведено.