Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12188/26480
DC FieldValueLanguage
dc.contributor.authorLenche Velkoska-Markovska, Biljana Petanovska-Ilievska, Aleksandar Markovskien_US
dc.date.accessioned2023-05-14T23:41:47Z-
dc.date.available2023-05-14T23:41:47Z-
dc.date.issued2023-01-
dc.identifier.urihttp://hdl.handle.net/20.500.12188/26480-
dc.description.abstractA reversed-phase high-performance liquid chromatography (RP-HPLC) method for determination of some pesticide residues in different water samples has been developed and validated. The investigated pesticides belong to a different chemical classes, such as: organonitrogen, among which triazines (e.g., atrazinе), organophosphorus (e.g., malathion, fenitrothion, parathion) and phenoxycarboxylic acids (e.g., 2,4-D (2,4-dichlorophenoxy)acetic acid)), which have different chemical structures and polarities. A Purospher STAR RP-8e (30 x 4 mm, 5 µm) analytical column, mobile phase consisted of acetonitrile and water, flow rate of 1 mL/min and constant column temperature at 25 °C were used for successful separation and quantitative determination of target analytes. The UV-detection was performed at 220 nm and 270 nm. Concentration and clean-up of analytes were done by solid-phase extraction (SPE). The developed method was validated according to European Commission guidelines for pesticide residue analytical methods and specificity, selectivity, linearity, precision, accuracy, and limit of quantification (LOQ) were tested for that purpose. The obtained values for relative standard deviation of retention times and peak areas (RSD ≤ 11.26 %), recoveries ranged from 95.01 - 111.20 %, multiple correlation coefficients (R2 ≥ 0.99) revealed that all performance characteristics were found within acceptance criteria. The method was successfully applied for determination of target pesticide residues in different water samples.en_US
dc.language.isoenen_US
dc.publisherActa Scientific Agricultureen_US
dc.relation.ispartofActa Scientific Agricultureen_US
dc.subjectmethod validation, pesticide residues, RP-HPLC, water samplesen_US
dc.titleApplication of RP-HPLC method for the analysis of some pesticide residues in water samplesen_US
dc.typeJournal Articleen_US
item.fulltextWith Fulltext-
item.grantfulltextopen-
Appears in Collections:Faculty of Agricultural Sciences and Food: Journal Articles
Files in This Item:
File Description SizeFormat 
final.pdf500.84 kBAdobe PDFView/Open
Show simple item record

Page view(s)

70
checked on May 11, 2024

Download(s)

27
checked on May 11, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.