Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12188/21462
Title: DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR DETERMINATION OF SOME PESTICIDE RESIDUES IN WATER SAMPLES
Authors: Velkoska-Markovska, Lenche
Petanovska-Ilievska, Biljana
Keywords: RP-HPLC; UV-DAD; method validation; pesticide residues; water samples
Issue Date: 2019
Publisher: Macedonian Academy of Sciences and Arts
Journal: MACEDONIAN ACADEMY OF SCIENCES AND ARTS, SECTION OF NATURAL, MATHEMATICAL AND BIOTECHNICAL SCIENCES, CONTRIBUTIONS
Abstract: The development of a new reversed-phase high-performance liquid chromatography method (RP-HPLC) with ultraviolet-diode array detection (UV-DAD) for simultaneous determination of 2,4-D, atrazine, malathion, fenitrothion and parathion residues in different water samples are described in this paper. The developed method has been validated according to European Commission guidelines for pesticide residue analytical methods, and all performance characteristics were found within acceptance criteria. The best separation and quantitative determination of the analytes were achieved using a LiChrospher 60 RP-select B (250 × 4 mm, 5 µm) analytical column, under the isocratic elution with mobile phase consisting of acetonitrile/water (60/40, V/V), flow rate of 1 ml/min, constant column temperature at 25 °C and UV-detection at 220 nm and 270 nm. The run time of analysis under the stipulated chromatographic conditions was about 10 min.
URI: http://hdl.handle.net/20.500.12188/21462
DOI: 10.20903/csnmbs.masa.2019.40.2.141
Appears in Collections:Faculty of Agricultural Sciences and Food: Journal Articles

Files in This Item:
File Description SizeFormat 
final trud.pdf730.11 kBAdobe PDFView/Open
Show full item record

Page view(s)

25
checked on May 1, 2024

Download(s)

11
checked on May 1, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.