Ве молиме користете го овој идентификатор да го цитирате или поврзете овој запис: http://hdl.handle.net/20.500.12188/7110
Наслов: Assessment of damaged timber structures using proof load test-Experience from case studies
Authors: Arangjelovski Toni
Gramatikov Kiril
Docevska Marija
Keywords: Glued laminated timberTimber bridgeAssessmentProof load testReliability
Issue Date: 30-дек-2015
Publisher: Elsevier
Journal: Construction and Building Materials
Abstract: In this paper assessment of damaged timber structures using proof load test is given, which is mandatory according to Macedonian standards. Two types of structures were analyzed in the paper: Glued laminated timber structure, Cambered beam span of L = 24.00 m and Glued Laminated pedestrian timber bridge, two-hinged arch, span of L = 26.00 m plus two simple supported beams span of L = 12.5 m each. The results were also used for reliability verification to define partial safety factor for material for ultimate limit state and serviceability limit state, according to Eurocodes EN1990 and EN1995.
URI: http://hdl.handle.net/20.500.12188/7110
DOI: doi.org/10.1016/j.conbuildmat.2015.07.010
Appears in Collections:Faculty of Civil Engineering: Journal Articles

Прикажи целосна запис

Page view(s)

87
Last Week
0
Last month
checked on 22.4.2024

Google ScholarTM

Проверете

Altmetric


Записите во DSpace се заштитени со авторски права, со сите права задржани, освен ако не е поинаку наведено.