Title: | Assessment of damaged timber structures using proof load test-Experience from case studies | Authors: | Arangjelovski Toni Gramatikov Kiril Docevska Marija |
Keywords: | Glued laminated timberTimber bridgeAssessmentProof load testReliability | Issue Date: | 30-Dec-2015 | Publisher: | Elsevier | Journal: | Construction and Building Materials | Abstract: | In this paper assessment of damaged timber structures using proof load test is given, which is mandatory according to Macedonian standards. Two types of structures were analyzed in the paper: Glued laminated timber structure, Cambered beam span of L = 24.00 m and Glued Laminated pedestrian timber bridge, two-hinged arch, span of L = 26.00 m plus two simple supported beams span of L = 12.5 m each. The results were also used for reliability verification to define partial safety factor for material for ultimate limit state and serviceability limit state, according to Eurocodes EN1990 and EN1995. | URI: | http://hdl.handle.net/20.500.12188/7110 | DOI: | doi.org/10.1016/j.conbuildmat.2015.07.010 |
Appears in Collections: | Faculty of Civil Engineering: Journal Articles |