Ве молиме користете го овој идентификатор да го цитирате или поврзете овој запис: http://hdl.handle.net/20.500.12188/21569
Наслов: Determination of veterinary drug residues, mycotoxins, and pesticide residues in bovine milk by liquid chromatography electrospray ionisation –tandem mass spectrometry
Authors: Hajrulai-Musliu, Zehra
Uzunov, Risto
Jovanov, Stefan
Kerluku, Maksud
Jankuloski, Dean 
Stojkovski, Velimir 
Pendovski, Lazo 
Sasanya, James Jacob
Keywords: veterinary drug residues, mycotoxins, pesticide residues, liquid chromatography electrospray ionisation–tandem mass spectrometry, validation.
Issue Date: 31-мај-2022
Publisher: Walter de Gruyter GmbH
Проект: Integrated Radiometric and Complementary Techniques for Mixed Contaminants and Residues in Food IAEA project D52041
Journal: Journal of Veterinary Research
Abstract: <jats:title>Abstract</jats:title> <jats:sec id="j_jvetres-2022-0027_s_006"> <jats:title>Introduction</jats:title> <jats:p>Multi-class and multi-residue analyses are very complex procedures because of the physico-chemical properties of veterinary drug residues and other contaminants. The purpose of the study was to develop an analytical method for the sensitive determination of 69 analytes in bovine milk by liquid chromatography electrospray ionisation–tandem mass spectrometry.</jats:p> </jats:sec> <jats:sec id="j_jvetres-2022-0027_s_007"> <jats:title>Material and Methods</jats:title> <jats:p>Antimicrobial, anabolic hormone, lactone, β-agonist, mycotoxin and pesticide residues were analysed in 120 raw milk samples from different dairy farms in North Macedonia. Stable isotopically labelled internal standards were used to facilitate effective quantification of the analytes.</jats:p> </jats:sec> <jats:sec id="j_jvetres-2022-0027_s_008"> <jats:title>Results</jats:title> <jats:p>The linear regression coefficients were higher than 0.99, the limits of detection ranged from 0.0036 to 47.94 μg/L, and the limits of quantification ranged from 0.053 to 59.43 μg/L. The decision limit values ranged from 0.062 to 211.32 μg/L and the detection capability from 0.080 to 233.71 μg/L. Average recoveries of the analytes spiked in raw milk were in the range of 70.83% to 109%, intra-day coefficient of variation (CV) values from 2.41% to 22.29%, and inter-day CV values from 3.48% to 23.91%. The method was successfully applied in the testing of bovine milk samples. In five samples residues were detected. They were sulfadimethoxine (in two samples), enrofloxacin, tetracycline and oxytetracycline and were at concentrations below the EU maximum residue limit.</jats:p> </jats:sec> <jats:sec id="j_jvetres-2022-0027_s_009"> <jats:title>Conclusion</jats:title> <jats:p>The method is useful for routine testing for this group of chemical hazards in bovine milk.</jats:p> </jats:sec>
URI: http://hdl.handle.net/20.500.12188/21569
DOI: 10.2478/jvetres-2022-0027
Appears in Collections:Faculty of Veterinary Medicine: Journal Articles

Files in This Item:
File Опис SizeFormat 
10.2478_jvetres-2022-0027.pdf1.37 MBAdobe PDFView/Open
Прикажи целосна запис

Page view(s)

49
checked on 10.5.2024

Download(s)

2
checked on 10.5.2024

Google ScholarTM

Проверете

Altmetric


Записите во DSpace се заштитени со авторски права, со сите права задржани, освен ако не е поинаку наведено.