Ве молиме користете го овој идентификатор да го цитирате или поврзете овој запис: http://hdl.handle.net/20.500.12188/16303
DC FieldValueLanguage
dc.contributor.authorNakov, Natalijaen_US
dc.contributor.authorBogdanovska, Liljanaen_US
dc.contributor.authorAcevska, Jelenaen_US
dc.contributor.authorTonic-Ribarska, Jasminaen_US
dc.contributor.authorPetkovska, Rumenkaen_US
dc.contributor.authorDimitrovska, Anetaen_US
dc.contributor.authorKasabova, Liliaen_US
dc.contributor.authorSvinarov, Dobrinen_US
dc.date.accessioned2022-01-26T10:35:45Z-
dc.date.available2022-01-26T10:35:45Z-
dc.date.issued2016-11-30-
dc.identifier.urihttp://hdl.handle.net/20.500.12188/16303-
dc.description.abstractIn this research, as a part of the development of fast and reliable HPLC-MS/MS method for quantification of ibuprofen (IBP) enantiomers in human plasma, the possibility of IBP acylglucoronide (IBP-Glu) back-conversion was assessed. This involved investigation of in source and in vitro back-conversion. The separation of IBP enantiomers, its metabolite and rac-IBP-d3 (internal standard), was achieved within 6 min using Chiracel OJ-RH chromatographic column (150 × 2.1 mm, 5 μm). The followed selected reaction monitoring transitions for IBP-Glu (m/z 381.4 → 205.4, m/z 381.4 → 161.4 and m/z 205.4 → 161.4) implied that under the optimized electrospray ionization parameters, in source back-conversion of IBP-Glu was insignificant. The results obtained after liquid-liquid extraction of plasma samples spiked with IBP-Glu revealed that the amount of IBP enantiomers generated by IBP-Glu back-conversion was far <20% of lower limit of quantification sample. These results indicate that the presence of IBP-Glu in real samples will not affect the quantification of the IBP enantiomers; thereby reliability of the method was improved. Additional advantage of the method is the short analysis time making it suitable for the large number of samples. The method was fully validated according to the EMA guideline and was shown to meet all requirements to be applied in a pharmacokinetic study.en_US
dc.language.isoenen_US
dc.publisherOxford University Press (OUP)en_US
dc.relation.ispartofJournal of chromatographic scienceen_US
dc.titleHigh-Throughput HPLC-MS/MS Method for Quantification of Ibuprofen Enantiomers in Human Plasma: Focus on Investigation of Metabolite Interferenceen_US
dc.typeJournal Articleen_US
dc.identifier.doi10.1093/chromsci/bmw166-
dc.identifier.urlhttps://academic.oup.com/chromsci/article/54/10/1820/2527517/HighThroughput-HPLCMSMS-Method-for-Quantification-
dc.identifier.volume54-
dc.identifier.issue10-
item.fulltextNo Fulltext-
item.grantfulltextnone-
crisitem.author.deptFaculty of Pharmacy-
crisitem.author.deptFaculty of Pharmacy-
crisitem.author.deptFaculty of Pharmacy-
crisitem.author.deptFaculty of Pharmacy-
crisitem.author.deptFaculty of Pharmacy-
Appears in Collections:Faculty of Pharmacy: Journal Articles
Прикажи едноставен запис

Page view(s)

163
checked on 23.6.2025

Google ScholarTM

Проверете

Altmetric


Записите во DSpace се заштитени со авторски права, со сите права задржани, освен ако не е поинаку наведено.