DETERMINATION OF BISPHENOL A IN BEVERAGES BY RP-HPLC
Journal
Agriculture & Forestry
Date Issued
2019
Author(s)
Biljana PETANOVSKA-ILIEVSKA, Mirjana S. JANKULOVSKA, Lenche VELKOSKA-MARKOVSKA, Jasmina SPASOVSKA
DOI
10.17707/AgricultForest.65.1.24
Abstract
Bisphenol A (BPA) is a monomer widely used in the production of polycarbonate, epoxy resins, diacrylates and phenolic resins. A small quantity of BPA can migrate into the food and thus it can be potential hazard for human health and environment. Therefore, quantitative determination of BPA is of a great importance. A fast, simple, precise and economic RP-HPLC method with UV-DAD detection for quantitative determination of BPA in beverages was developed. Three different analytical columns were tested: Hypersil ODS (250 mm x 4.6 mm; 5 µm), LiChrospher 60 RP-Select B (125 mm x 4 mm; 5 µm) and Purospher® STAR RP-18 endcapped (30 mm x 4 mm; 3 µm). Analyzed beverages were packed in plastic bottles and small glass bottles closed with a
cops coated with epoxy resin on inside. For quantitative determination of BPA following experimental conditions were established: mobile phase consisted of acetonitrile/water 50/50 (v/v), flow rate of 1 mL/min, column temperature of 25 oС, injection volume of 5 µL and UV detection at 200 nm. The method was developed in an isocratic manner and with a reversed phase column. Prior the analyses the samples were filtrated through syringe filters Spartan – T with pore
size 0.45 µm. The following parameters were determined: retention time, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, selectivity and sensitivity. The RP-HPLC method with UV-DAD detection can be successfully used for quantitative determination of BPA in non alcoholic beverages without pre-treatment. The BPA was not detected in the
analyzed beverages.
cops coated with epoxy resin on inside. For quantitative determination of BPA following experimental conditions were established: mobile phase consisted of acetonitrile/water 50/50 (v/v), flow rate of 1 mL/min, column temperature of 25 oС, injection volume of 5 µL and UV detection at 200 nm. The method was developed in an isocratic manner and with a reversed phase column. Prior the analyses the samples were filtrated through syringe filters Spartan – T with pore
size 0.45 µm. The following parameters were determined: retention time, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, selectivity and sensitivity. The RP-HPLC method with UV-DAD detection can be successfully used for quantitative determination of BPA in non alcoholic beverages without pre-treatment. The BPA was not detected in the
analyzed beverages.
Subjects
File(s)![Thumbnail Image]()
Loading...
Name
Agriculture and forestry - Jankulovska 2019.pdf
Size
367.81 KB
Format
Adobe PDF
Checksum
(MD5):cf57a2208c4adef50752826650b2d8a6
