Majstorov, Venjamin
Preferred name
Majstorov, Venjamin
Official Name
Majstorov, Venjamin
Main Affiliation
Email
v.majstorov@medf.ukim.edu.mk
43 results
Now showing 1 - 10 of 43
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Молекуларна нуклеарна медицина: први искуства со визуализација на дистрибуцијата на соматостатинските рецептори(Medical Faculty, Ss. Cyril and Methodius University in Skopje, 2011); ; ;Здравеска-Кочовска М - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Universal salt iodization potentially contributes to health equity: socio-economic status of children does not affect iodine status(Walter de Gruyter GmbH, 2022-09-27) ;Milevska-Kostova, Neda; ; ; Ittermann, TillMany studies have shown that socio-economic status (SES) contributes to health inequalities, with nutrition as one of the major risk factors. Iodine intake entirely depends on external sources, and deficiencies are known to be more prevalent in lower social groups, especially in countries with limited access to iodized salt. This study aimed to determine the influence of SES on iodine status and iodine availability from household salt in North Macedonia. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Gender differences in detecting coronary artery disease with dipyridamole stress myocardial perfusion imaging using 99m-Tc sestamibi gated SPECT(Macedonian Academy of Science and Art (MANU), 2005-08-26); ; ; ; Peovska, IrenaThere are some specifics in the presentation of coronary artery disease (CAD) in women compared with men that may cause diagnostic pitfalls. The accuracy of noninvasive diagnostic testing in women tends to be lower than that in men. Stress myocardial perfusion imaging with 99m-Tc sestamibi gated SPECT is an accurate technique for detecting CAD. Only a few studies have compared dipyridamole stress imaging according to gender. The aim of the study was to compare the diagnostic value of dipyridamole myocardial perfusion imaging with 99m-Tc sestamibi gated SPECT in detecting CAD among patients of both sexes. We studied 62 consecutive patients (38 men, 24 women) using 99m-Tc sestamibi gated SPECT and dipyridamole stress to detect CAD. All the patients also underwent coronary angiography. Overall regional sensitivity was significantly lower in women compared with men (71.4% vs. 92.7%, p=0.039). There were no significant differences for detecting CAD in individual coronary arteries, although regional sensitivity in all three vascular territories was higher in men compared to women. The lowest sensitivity in women was found in the LAD territory (66.6%). Overall regional specificity in men and women was similar and did not reach statistical significance (88.7% vs. 94.7%). Significantly lower specificity in men was found only in the RCA territory (79.1%), compared with that in women (100%). Our results confirmed that there are certain gender differences in the diagnostic performance of dipyridamole stress myocardial perfusion imaging with 99-Tc sestamibi gated SPECT which are assigned to the characteristics of the female population. However, the diagnostic accuracy is also quite high in women, which makes this technique efficient enough in detecting CAD among this population. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Demographic and Clinical Features of Thyroid Carcinomas in Republic of Macedonia (1999-2010)(ID Design 2012/Scienfitic Foundation SPIROSKI, 2017-12-15); ; ; ; Thyroid carcinomas (TC) are the most common endocrine malignancies. In some parts of the world, the incidence of TCs has increased over the past few decades, especially in females according to some studies. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, The Current State of Nuclear Nephrology in Modern Medicine(Macedonian Academy of Sciences and Arts/Walter de Gruyter GmbH, 2023-12-01); ; ; ; Poposka, DanielaGlomerular filtration rate (GFR) is the most reliable parameter of renal function. Regarding the complexity of the gold standard inulin clearance, different estimating equations have been developed with CKD-EPI creatinine equation recommended as the most reliable one. In some clinical situations where creatinine based equations might not be valid, alternative methods are needed. Nuclear medicine methods for measuring GFR with 51Cr EDTA and 99mTc DTPA have been widely used for decades. There are different methodologies for the measurement of kidney function with radiopharmaceuticals: urinary clearance, plasma clearance, multiple plasma sampling, slope intercept, single sample plasma equation, slope only, and the gamma camera-based method. Greater precision of measuring GFR is needed in certain clinical situations. The most common are diagnosis and follow up of chronic kidney disease and definition of the beginning of replacement therapy. The assessment of renal function is also important for potential kidney donors. In recent years, with the introduction of new chemotherapeutic drugs and targeted therapy, oncologic patients treated with nephrotoxic drugs have become more commonly referred for measuring GFR. The monitoring of renal function is important during treatment in order to detect the transformation from reversible acute kidney injury to irreversible chronic kidney disease as well as in the cases of renal insufficiency reduce the dosage and prevent accumulation of the drug and avoid dosage related toxic effects. Assessment of kidney function using measured mGFR will be an important milestone in the creation of more accurate and expanding personalized medicine principle in current onconephrology practice. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Impact of COVID-19 on Cardiovascular Testing in the United States Versus the Rest of the World: The INCAPS-COVID Study(Elsevier BV, 2021-06-10) ;Hirschfeld, Cole B ;Shaw, Leslee J ;Williams, Michelle C ;Lahey, RyanVillines, Todd CThis study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Vesicoureteral Reflux Detected with (99m)Tc-DTPA Renal Scintigraphy during Evaluation of Renal Function(ID Design Press/Scienfitic Foundation SPIROSKI, 2016-03-15); ; ; ; Radionuclide techniques, as direct radionuclide cystography and (99m)Tc-DMSA scintigraphy, have been used in evaluation of vesicoureteral reflux (VUR) and reflux nephropathy (RN) in children. Dynamic (99m)Tc-DTPA scintigraphy is reserved for evaluation of differential renal function and obstruction in children, where hydronephrosis is detected by ultrasonography (US) pre- or postnatally. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Myocardial perfusion in patients with systemic lupus erythematosus and low to intermediate risk for coronary artery disease, assessed with 99mtc mibi myocardial perfusion scintigraphy –case reports(2017-06) ;Sandevska, Emilija; ; ;Damjanovska Krstic, LjubinkaObjective: Due to early and accelerated atherosclerosis, the patients with systemic lupus erythematosus (SLE), asymptomatic for coronary artery disease (CAD) are in particular risk of acute myocardial infarction (AMI). A diagnostic approach for their risk stratification is needed, followed with appropriate management and treatment. Material and Methods: We present three patents with SLE, from two patients cohorts (younger and older-age group), with SLE history for more than 7 years, with more active phase of disease (SLEDAI score 3-5) and atypical chest pain. With low to intermediate risk for CAD according to traditional risk factors for CAD, but with presence of SLE–related risk factors for atherosclerosis, they underwent 99mTc Myocardial perfusion scintigraphy (MPS) (at rest and stress, as one-day protocol) for evaluation of myocardial perfusion and left ventricular (LV) functional abnormalities. Visual and quantitative analysis of perfusion and functional tomoscintigrams detected the presence of one (in 2 patients) or two vessel’s stress-induced ischemia (in 1 patient), with mild to severe intensity and 10-27% extent of ischemic LV myocardial mass. Regions with the perfusion abnormalities were accompanied with wall motion abnormality during the stress study. The global LV functional parameters were normal in both studies (stress vs rest) with higher transient dilation parameter (TID) in one patient, indicating the presence of more profound perfusion abnormalities. Two patients were referred for angiography which in both cases showed no evidence of significant coronary artery stenosis of the major coronary arteries. Along with their higher levels of serum concentrations of endothelin (ET-1) and C-reactive protein (CRP) the myocardial perfusion abnormalities resemble microvascular functional affection. Conclusion: We emphasize the importance of identification of asymptomatic high CAD risk patients with SLE and CAD evaluation in this patients' cohort in order to prevent premature cardiac death. Determination of the clinical pretest probability for CAD and assessment of myocardial perfusion with non-invasive imaging technique such as 99mTc SPECT MIBI MPS may help in detecting the patients that should be subjected to coronary angiography. Even in the case of microvascular dysfunction, without significant obstruction of coronary vassels, prevention and/or treatment of CAD traditional risk factors and better control of the SLE disease can prevent or postpone the accelerated development of atherosclerosis and the decrease the risk of cardiovascular events. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Ultrasonographic Findings in Patients with Benign and Malignant Thyroid Nodules who underwent Ultrasound Guided Fine Needle Aspiration Cytology(ID Design 2012/Scientific Foundation SPIROSKI, 2015-12-15)Patients with thyroid nodules represent common problem in daily routine of thyroidologists as well as other medical specialties. Fortunately only small number of thyroid nodules turns out to be malignant. Ultrasound is most frequently used imaging modality in the evaluation of thyroid nodules and certain ultrasonographic features are associated with greater risk for malignancy.
