Наслов: Analysis of values from the climatic curve and heat load on the water losses in TPP „Bitola“
Authors: Mijakovski, Vladimir
Mojsovski, Filip 
Lutovska, Monika
Keywords: heat, mass, losses, water
Issue Date: мај-2019
Publisher: Faculty of Mechanical Engineering, University of Banja Luka
Conference: 14th International Conference on Accomplishments in Mechanical and Industrial Engineering - DEMI 2019
Abstract: Heat transfer is conducted through latent heat transfer and is proportional to the change in absolute humidity. Since the input temperature of the dry air thermometer or the relative humidity affect the latent/sensible heat ratio, they also affect the amount of evaporated - lost water.
URI: http://hdl.handle.net/20.500.12188/8828
ISBN: 978-99938-39-85-9