dc.description.abstractAccording to official fire statistics, chimney fires account for almost 20% of all fires that occur in family residential buildings every year in the Balkan region. The high temperature from the chimneys may have an influence on fire spreading to the wooden girders. The objective of the study was to gather and analyse data on timber structure fire incidents occurring in family residential buildings in lowland rural settlements in Serbia (2010-2014) and a mountain settlement in Montenegro (2007-2013) in order to determine the extent to which existing data can be used in fire risk assessment. Additionally, the chimney-timber floor heat transfer mech anism was investigated, namely, the time dependent temperature distribution in the cross-section of few types of mostly used chimneys and floor structures were analysed. This research illustrates how the lack of chimney maintenance and social vulnerability of the settlements (aged rural population with low incomes, living in many cases alone in old houses in areas with limited access to distance heating systems or piped gas) could influence the fire risk in timber structures in rural low land and mountain areas. It is shown that significant differences exist with respect to fire causation over time and the type of wooden structural elements – due to different temperature distribution in the cross-sections of the floor structure, both in lowland and mountain settlementsen_US
dc.language.isoenen_US
dc.publisherVinca Inst Nuclearen_US
dc.relation.ispartofThermal Scienceen_US
dc.relation.ispartofseriesVol. 25;No. 3A-
dc.subjectchimneysen_US
dc.subjectrisk analysisen_US
dc.subjectresidential buildingsen_US
dc.titleCHIMNEYS' INFLUENCE ON FIRE RISK OF SOLID WOOD STRUCTURES IN RESIDENTIAL BUILDINGS IN RURAL BALKAN SETTLEMENTSen_US
dc.typeArticleen_US
dc.identifier.doi10.2298/TSCI190525138L-
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:Faculty of Civil Engineering: Journal Articles
Files in This Item:
File Опис SizeFormat 
Laban_0354-98362000138L.pdf2.1 MBAdobe PDFView/Open
Прикажи едноставен запис

Page view(s)

21
checked on 20.5.2024

Download(s)

2
checked on 20.5.2024

Google ScholarTM

Проверете

Altmetric


Записите во DSpace се заштитени со авторски права, со сите права задржани, освен ако не е поинаку наведено.