Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12188/23204
DC FieldValueLanguage
dc.contributor.authorUzunov, Ristoen_US
dc.contributor.authorHajrulai musliu, Zehraen_US
dc.contributor.authorJovanov, Stefanen_US
dc.contributor.authorDimitrieska Stojkovikj, Elizabetaen_US
dc.contributor.authorAngeleska, Aleksandraen_US
dc.contributor.authorStojanovska Dimzoska, Biljanaen_US
dc.contributor.authorStojkovski, Velimiren_US
dc.date.accessioned2022-09-29T20:03:43Z-
dc.date.available2022-09-29T20:03:43Z-
dc.date.issued2022-09-22-
dc.identifier.urihttp://hdl.handle.net/20.500.12188/23204-
dc.description.abstractMethyltestosterone is a synthetic anabolic steroid that can be used in meat production animals to improve the weight gain and the meat/fat-ratio, but the residues of this anabolic steroid in meat present a potential risk for public health. In the European Union and most countries worldwide the use of methyltestosterone and other anabolic steroids as growth promoter in livestock production is completely banned. In this study an enzyme-linked immunosorbent assay (ELISA) screening method for detection of methyltestosterone in urine and meat has been validated according to the Regulation (EU) 2021/808. Regulation (EU) 2021/808 is a new regulation that replaces the Commission Decision 2002/657. The sample preparation procedure for urine involved hydrolysis and clean-up with solid phase extraction (SPE) using C18 cartridges, while the sample preparation for muscle included extraction with methanol, defatting with hexane and cleanup with SPE using C18 cartridges. The concentrations of the residues were measured with ELISA reader at 450 nm. In the validation procedure were included linearity, selectivity/ specifi city, limit of detection (LOD), decision limit (CCβ), trueness (expressed through recovery) and precision (expressed through repeatability and reproducibility). The method demonstrated excellent linearity with coeffi cient of variation (R2) 0.9966 for urine and 0.9997 for muscle, in the calibration range from 0.125 to 4.5 μg/L. The results for selectivity/ specifi city indicated that there are not matrix interferences. LOD was 0.25 μg/l for urine and 0.25 μg/kg for muscle, while CCβ was 0.45 μg/l for urine and 0.60 μg/kg for muscle. These values for CCβ were lower than new Minimum Method Performance Requirements (MMPR) values for methyltestosterone. The new MMPR values for methyltestosterone, which were adopted in 2020, for urine is 0.5 μg/l, while for muscle is 1.0 μg/kg. The method yielded acceptable recovery rate between 70-120% in the fortifi ed samples from urine and muscle. The coeffi cient of variation (CV) for repeatability was less than 15.0 %, while the CV for reproducibility was less than 20.0%. The method fulfi ls the criteria prescribed in Regulation (EU) 2021/808 and can be used as rapid screening method for the routine detection of methyltestosterone in urine and muscle.en_US
dc.language.isoenen_US
dc.publisherSs. CYRIL AND METHODIUS UNIVERSITY IN SKOPJE FACULTY OF VETERINARY MEDICINE - SKOPJEen_US
dc.subjectmethyltestosterone, urine, muscle, validation, Regulation (EU) 2021/808en_US
dc.titleValidation of the rapid ELISA method for determination of methyltestosterone in urine and muscle based on the new regulation (EU) 2021/808en_US
dc.typeProceeding articleen_US
dc.relation.conference9th International Scientifi c Meeting, Days of veterinary medicine 2022 22-25 September 2022, Ohrid, R. N. Macedoniaen_US
item.grantfulltextopen-
item.fulltextWith Fulltext-
crisitem.author.deptFaculty of Veterinary Medicine-
crisitem.author.deptFaculty of Veterinary Medicine-
crisitem.author.deptFaculty of Veterinary Medicine-
crisitem.author.deptFaculty of Veterinary Medicine-
Appears in Collections:Faculty of Veterinary Medicine: Conference papers
Files in This Item:
File Description SizeFormat 
Uzunov i dr dvm 2022.pdf2.1 MBAdobe PDFView/Open
Show simple item record

Page view(s)

134
checked on May 20, 2024

Download(s)

36
checked on May 20, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.