Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
User Manual
Have you forgotten your password?
  1. Home
  2. Faculty of Medicine
  3. Faculty of Medicine: Conference papers
  4. DOSIMETRIC EVALUATION OF TWO DIFFERENT BRACHYTHERAPY TECHNIQUES FOR INOPERABLE UTERINE CERVIX CANCER
Details

DOSIMETRIC EVALUATION OF TWO DIFFERENT BRACHYTHERAPY TECHNIQUES FOR INOPERABLE UTERINE CERVIX CANCER

Date Issued
2017-06-12
Author(s)
Abstract
Objective: To evaluate an alternative brachytherapy technique for inoperable uterine cervix cancer, without increasing the risk of toxicity and trying to achieve the same local control of the disease.
Material and methods: Comparative study was undertaken in order to two different high-dose rate intracavitary brachytherapy applicators to be compared: intrauterine tandem/ring applicators and vaginal cylinder. Prescribed doses were 7 Gy at point A for tandem/ring applicators and 7 Gy at 10 mm from the top of the cylinder applicator. Doses delivered to the rectum, bladder and sigmoid colon were kept below the tolerance limits. Volumes covered by the 100% isodoses, (V100), were compared.
Analyzed were 40 patients, treated in University Clinic of Radiotherapy and Oncology - Skopje in period from May to July 2016, all with locally advanced cervical cancer and realized percutaneous definitive chemoradiotherapy. In 13 of them (32.5%) intracavitary brachytherapy was made with tandem/ring applicators (tandem being 4 cm long) and prescribed dose of 7 Gy at point A. The remaining 27 patients (67.5%) due to lack of conditions for tandem/ring application, brachytherapy treatment was implemented with vaginal cylinder and prescribed dose 7 Gy at 10 mm from the top of the applicator.
Results: In order to obtain net tissue which is included in 100% isodose volume, the volumes of cylinder applicators and ring buildups were excluded from the treated volume. The 100% tissue volumes formed in tandem/ring applications and cylinder applications were on average 50,64 cc and 34.80 ss respectively after they were diminished on average by 7.04 cc and 12.90 cc respectively. Because the process of finding tissue volume for the cylinder applications had several steps the uncertainty in determining this volume was 1.24%. Comparing 100% isodose volumes we can conclude that their means differ at the 0.05 level of significance, p value being less than 0.001.
Conclusion: Vaginal applicator may not be used as an alternative therapy technique for patients affected by uterine cervix cancer who does not allow application of tandem/ring applicators.
Subjects

cervical cancer

intracavitary brachyt...

dosimetry

File(s)
Loading...
Thumbnail Image
Name

Book_of_Abstracts-RAD_2017.pdf

Description
str.463
Size

17.75 MB

Format

Adobe PDF

Checksum

(MD5):76e6a464875dbf7dad5cb0ed8d2d5c08

Loading...
Thumbnail Image
Name

presentation.RAD 2017.pptx

Size

2.19 MB

Format

Microsoft Powerpoint XML

Checksum

(MD5):a3cf49163241065b38404349a8a27cd9

⠀

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify