Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12188/9028
Title: Comparison of two-dimenzional and three-dimensional echocardiography in determination od left ventricle volumes and ejection fraction in adult population.
Authors: Bushljetikj O
Georgievska-Ismail, Lj 
Keywords: Three-dimensional echocardiography
Left ventricle volume
Issue Date: Dec-2017
Publisher: Macedonian Academy of Sciences and Arts
Journal: Prilozi (Makedonska akademija na naukite i umetnostite. Oddelenie za medicinski nauki) 
Abstract: Introduction: Left ventricle (LV) volumes and ejection fraction (EF) determined with two-dimensional echocardiography (2DE) and three-dimensional echocardiography (3DE) show significant differences.The aim of this study is to determine the agreement of the measurements of LV volumes and EF with 2DE and 3DE in the general adult population, with preserved LV systolic function. Material and methods: In 52 subjects, older than 65 years, LV end-diastolic volume index (EDVi), end-systolic volume index (ESVi) and EF were measured with 2DE and 3DE according to the official recommendations, and reproducibility of both methods and their agreement were determined. Results: Intraclass correlation coefficient for intra-observer reproducibility in the measurement of EDVi, ESVi and EF with 2DE was 0.861, 0.891 and 0.917 respectively, whereas with 3DE 0.854, 0.893 and 0.913, respectively. The difference in the measurement of EDVi and ESVi was significant (p<0.001) whereas the measurement of EF was insignificant (p=0.153). The mean difference value EDVi and ESVi determined with 2DE and 3DE was 5.6+/-5.21 and 3.01+/-2.69 ml/m2 (p<0.001), and of EF 0.306+/-1.475%. Spear- man’s correlation coefficient for EDV was 0.693, for ESV 0.763 and for EF 0.97. Conclusion: Larger LV volumes were measured in the adult population using 3DE compared to 2DE, but identical values for EF were obtained. This difference in the measured values could not be attributed to the largeness of the LV volume and EF itself.. 3DE demonstrated better intra-observer reproducibility for LV volumes and EF as a major parameter in many clinical decisions.
URI: http://hdl.handle.net/20.500.12188/9028
DOI: 10.2478/prilozi-2018-0011.
Appears in Collections:Faculty of Medicine: Journal Articles

Files in This Item:
File Description SizeFormat 
Bushljetic, Georgievska-2017.pdf943.77 kBAdobe PDFView/Open
Show full item record

Page view(s)

52
checked on Apr 19, 2024

Download(s)

25
checked on Apr 19, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.