Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12188/34298
DC FieldValueLanguage
dc.contributor.authorDameska, Angelaen_US
dc.contributor.authorTeodosievska Dilindarski, Milenaen_US
dc.contributor.authorLukarski, Dushkoen_US
dc.date.accessioned2025-11-06T12:00:03Z-
dc.date.available2025-11-06T12:00:03Z-
dc.date.issued2023-
dc.identifier.urihttp://hdl.handle.net/20.500.12188/34298-
dc.description.abstractVolumetric modulated arc therapy (VMAT) is the next step in the improvement of the dynamic intensity modulated radiotherapy by improving the delivery efficiency and reducing the treatment time. In this study we have evaluated the delivery accuracy of different types of VMAT plans by performing an end-to-end test using the CIRS IMRT Thorax 002LFC phantom on two different radiotherapy units, a Varian iX Clinac and a Halcyon unit. We have created 10 different VMAT plans and measured the dose in different points according to a modified IAEA CRP E24017 protocol. For the measurement points representing the target volumes we have found that using two or three arcs gives acceptable results, but for single arc treatments the results were suboptimal. For low-dose regions, field size was found to have a more pronounced effect especially on the iX unit, with larger fields leading to slightly reduced accuracy. Inaccuracies are usually highest where the inhomogeneity of the body is greatest, such as the points representing the lungs and the spinal cord regions, where the computational algorithms themselves also contribute to the overall inaccuracy. In conclusion, the end-to-end test showed that the plans are clinically acceptable, but the recommendations for these particular machines would be not to use single arc treatments and to consider algorithm inaccuracies in regions of greater inhomogeneity during the treatment planning process.en_US
dc.language.isoenen_US
dc.publisherSievert Associationen_US
dc.subjectVMATen_US
dc.subjectEnd-to-end testen_US
dc.subjectCIRS IMRT thorax phantomen_US
dc.titleEvaluating VMAT Delivery Accuracy Using End-to-End Test for Different Types of VMAT Plansen_US
dc.typeProceeding articleen_US
dc.relation.conferenceRAP Conference 2023en_US
dc.identifier.doi10.37392/RapProc.2023.27-
item.fulltextWith Fulltext-
item.grantfulltextopen-
crisitem.author.deptFaculty of Medicine-
Appears in Collections:Faculty of Medicine: Conference papers
Files in This Item:
File SizeFormat 
012 Dameska RAP2023.docx181.29 kBMicrosoft Word XMLView/Open
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.