Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12188/30188
DC FieldValueLanguage
dc.contributor.authorGoggins, Jamieen_US
dc.contributor.authorJiang, Yadongen_US
dc.contributor.authorBroderick, Brian M.en_US
dc.contributor.authorSalawdeh, Suhaiben_US
dc.contributor.authorO'Reilly, Gerard J.en_US
dc.contributor.authorElghazouli, Ahmed Y.en_US
dc.contributor.authorAlwahsh, Hatimen_US
dc.contributor.authorBogdanovic, Aleksandraen_US
dc.contributor.authorRakicevic, Zoranen_US
dc.contributor.authorGjorgjiev, Igoren_US
dc.contributor.authorPoposka, Angelaen_US
dc.contributor.authorPetreski, Borjanen_US
dc.contributor.authorMarkovski, Igoren_US
dc.date.accessioned2024-05-15T08:57:37Z-
dc.date.available2024-05-15T08:57:37Z-
dc.date.issued2021-09-
dc.identifier.urihttp://hdl.handle.net/20.500.12188/30188-
dc.description.abstract<jats:title>Abstract</jats:title><jats:p>The self‐centring system presented in this paper is a novel damage control technique designed to improve the resilience of concentrically braced frames (CBF) under seismic action. Namely, traditional CBFs can undergo large residual drifts following an earthquake event which can limit the opportunity for cost‐effective repair of the structure. Additionally, the gusset plates connecting the brace members to beams and/or columns can experience substantial rotations as a result of the compression buckling of the bracing members. Through the utilisation of post‐tensioning strands placed between flanges of beams, the novel self‐centring concentrically braced frame (SC‐CBF) system can return the frame to its original position after significant inelastic deformations experienced during large earthquakes, resulting in minimum residual drifts.</jats:p><jats:p>In this paper, shake table testing of the aforementioned SC‐CBF system subjected to realistic earthquake loading is presented. The research is carried out as part of the H2020 “Seismology and earthquake engineering research infrastructure alliance for Europe” SERA project. Four sets of bracing configurations, incorporating varying square hollow section (SHS) braces and gusset plates were utilised in the shake table testing. Uniaxial loading with varying shake table accelerations was executed and the structural response evaluated using data from strain gauges (SG), load cells (LC), displacement transducers and accelerometers. The measured results provide information on the important parameters such as the tensile and compressive strength of the braces, post‐buckling capacity, gusset plate strains and post‐tensioning force. These findings are then presented and the crucial local and global response performance emphasised.</jats:p>en_US
dc.publisherWileyen_US
dc.relation.ispartofce/papersen_US
dc.titleShake Table Testing of Self‐Centring Concentrically Braced Framesen_US
dc.typeArticleen_US
dc.identifier.doi10.1002/cepa.1508-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/pdf/10.1002/cepa.1508-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/full-xml/10.1002/cepa.1508-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/pdf/10.1002/cepa.1508-
dc.identifier.volume4-
dc.identifier.issue2-4-
dc.identifier.fpage1949-
dc.identifier.lpage1956-
item.fulltextNo Fulltext-
item.grantfulltextnone-
Appears in Collections:Institute of Earthquake Engineering and Engineering Seismology: Journal Articles
Show simple item record

Page view(s)

50
checked on Jul 19, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.