Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12188/27957
DC FieldValueLanguage
dc.contributor.authorGenadieva Dimitrova, Magdalenaen_US
dc.contributor.authorNeshkovski, Metodijaen_US
dc.contributor.authorPopova Jovanovska, Rozalindaen_US
dc.contributor.authorJoksimovikj, Nenaden_US
dc.contributor.authorTrajkovska, Merien_US
dc.contributor.authorMiloshevski, Mitkoen_US
dc.contributor.authorSerafimoski, Vladimiren_US
dc.date.accessioned2023-09-19T07:49:10Z-
dc.date.available2023-09-19T07:49:10Z-
dc.date.issued2005-08-
dc.identifier.issn0351-3254-
dc.identifier.urihttp://hdl.handle.net/20.500.12188/27957-
dc.description.abstractThe aim of the study is to evaluate the contrast enhanced power doppler technique as a method to detect and differentiate vascular patterns of focal liver lesions. Fourty-nine patients with focal liver lesions were included in the study, twenty-nine of them with malignant liver lesions (9 HCC, 20 metastatic), twenty patients with benign lesions (12 haemangiomas, 5 focal nodular hyperplasia, 3 focal steatosis). In all patients classic B-mode and power doppler sonography was performed prior to administration of the contrast medium Levovist (300 mg/ml) and a power doppler examination subsequent to medium administration. Contrast administration led to lowering the number of "no-flow" lesions from 19 to 11. Postcontrast scan analysis revealed markedly enhanced flow in 15 cases in comparison to only 4 in pre-contrast examinations. The pre-contrast power doppler showed central flow in 7, and peripheral in 26 focal liver lesions. On the other hand, the postcontrast study revealed a central flow in 14, and peripheral in 34 focal liver lesions. Statistical significance between pre- and post-contrast power doppler detection of vascularization existed in malignant focal liver lesions and haemangiomas. The same pre- and post-contrast evaluation proved to be statistically non-significant in the focal nodular hyperplasia and focal steatosis groups. Administration of contrast medium enables a better visualization of intratumor blood vessels in focal liver lesions. This, in combination with the power doppler technique, brings such scans close to angiographic findings.en_US
dc.language.isoenen_US
dc.relation.ispartofPrilozi (Makedonska akademija na naukite i umetnostite. Oddelenie za medicinski nauki)en_US
dc.titleContrast-enhanced power doppler sonography in detection and differentiation of focal liver lesionsen_US
dc.typeArticleen_US
dc.identifier.volume26-
dc.identifier.issue1-
item.fulltextWith Fulltext-
item.grantfulltextopen-
crisitem.author.deptFaculty of Medicine-
crisitem.author.deptFaculty of Medicine-
crisitem.author.deptFaculty of Medicine-
crisitem.author.deptFaculty of Medicine-
Appears in Collections:Faculty of Medicine: Journal Articles
Files in This Item:
File Description SizeFormat 
genadieva.pdf218.22 kBAdobe PDFView/Open
Show simple item record

Page view(s)

24
checked on May 11, 2024

Download(s)

2
checked on May 11, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.