Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12188/27618
DC FieldValueLanguage
dc.contributor.authorM. Zivkovic Hristovaen_US
dc.contributor.authorC. Volkanovska Ilijevskaen_US
dc.contributor.authorS. Jovanovska Mishevskaen_US
dc.date.accessioned2023-08-31T09:03:45Z-
dc.date.available2023-08-31T09:03:45Z-
dc.date.issued2023-02-
dc.identifier.urihttp://hdl.handle.net/20.500.12188/27618-
dc.description.abstractBackground and Aims Sensor-augmented pumps with predictive low-glucose suspend (SAP with PLGS) can be a good therapy option in countries where hybrid closed loop systems are not available. We present a case of a 25 year old patient with history of uncontrolled diabetes achieving CGM targets using SAP with PLGS (Medtronic Minimed 640G, Guardian Sensor 3). Methods Female patient diagnosed with type 1 diabetes at the age of 8, had a history of uncontrolled diabetes with MDI therapy. Despite optimizing parameters of flexible MDI her A1C during the last 6 years has been between 9.0-9.7%. Intermittent use of professional CGM confirmed high glucose variation and high average sensor glucose. Before initiating SAP her TDD was 54 units (0.8 u/kg), ICR 6 grams/U, ISF 2.0 mmol/L/U and glucose target 6.5mmol/l. After 5 days of 2 hours education SAP was initiated. CGM analysis was performed regularly on day 1, 3, 7 the first week of initiation and every 2 weeks thereafter using Medtronic CarelinkTM System Software. Fine tuning of settings was made during the online visits according to CGM parameters and weight reduction leading to TDD of 32U (0.6U/kg). In person visits were performed the 1st and 3rd month. Results After 90 consecutive days of sensor wear we achieved the following CGM metrics: 78% Time In Range, 3+1 % Time Below Range, 16+2 % Time Above Range, Average Sensor Glucose 7.8 mmol/l, Glucose Management Indicator of 6.7% and Coefficient of Variation 32%. Conclusions SAP with PLGS can be a helpful tool to achieving good glycemic control in selected patients.en_US
dc.language.isoenen_US
dc.publisherMary Ann Liebert, Incen_US
dc.relation.ispartofDIABETES TECHNOLOGY & THERAPEUTICSen_US
dc.subjectSAPen_US
dc.subjectPLGSen_US
dc.subjectTIRen_US
dc.titleREACHING CONTINUOUS GLUCOSE MONITORING TARGETS WITH SENSOR-AUGMENTED PUMP: A CASE REPORTen_US
dc.typeProceeding articleen_US
dc.relation.conferenceATTD Advanced Technologies & Treatments for Diabetes Conference 22‐25 February 2023 I Berlin & Onlineen_US
dc.identifier.doi10.1089/dia.2023.2525.abstracts-
item.grantfulltextopen-
item.fulltextWith Fulltext-
crisitem.author.deptFaculty of Medicine-
crisitem.author.deptFaculty of Medicine-
Appears in Collections:Faculty of Medicine: Conference papers
Files in This Item:
File Description SizeFormat 
ATTD2023 (2).png57.02 kBimage/pngThumbnail
View/Open
ATTD2023.png92.96 kBimage/pngThumbnail
View/Open
Show simple item record

Page view(s)

71
checked on May 21, 2024

Download(s)

18
checked on May 21, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.