Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12188/20777
DC FieldValueLanguage
dc.contributor.authorLameski, Petreen_US
dc.contributor.authorZdravevski, Eftimen_US
dc.contributor.authorKoceski, Sasoen_US
dc.contributor.authorKulakov, Andreaen_US
dc.contributor.authorTrajkovikj, Vladimiren_US
dc.date.accessioned2022-07-14T11:40:25Z-
dc.date.available2022-07-14T11:40:25Z-
dc.date.issued2017-03-31-
dc.identifier.urihttp://hdl.handle.net/20.500.12188/20777-
dc.description.abstractPatient monitoring in intensive care units requires collection and processing of high volumes of data. High sensitivity of sensors leads to significant number of false alarms, which cause alarm fatigue. Reduction of false alarms can lead to better reaction time of medical personnel. This paper aims to develop a method for false alarm suppression and evaluate it on a publicly available data set with manually annotated alarms. First, an automated feature engineering was performed using the signal for arterial blood pressure (ABP) and a processed signal that contained the times of each heartbeat from the ABP signal. Next, support vector machines, random forest, and extreme random trees classifiers were trained to create classification models. The best suppression performance was achieved for the extreme tachycardia alarm, for which 90.3% of the false alarms were suppressed, while only 0.54% of the true alarms were incorrectly suppressed. This paper demonstrates that alarm suppression can be achieved with high accuracy using an automated feature engineering coupled with machine learning algorithms. The proposed approach can be utilized as aid to medical personnel and experts, allowing them to be more productive and to respond to alarms in a more timely manner.en_US
dc.publisherIEEEen_US
dc.relation.ispartofIEEE Accessen_US
dc.subjectMachine learning, medical expert systems, signal processing, patient monitoring, time series analysis, pattern recognition, data preprocessingen_US
dc.titleSuppression of intensive care unit false alarms based on the arterial blood pressure signalen_US
dc.typeJournal Articleen_US
item.fulltextWith Fulltext-
item.grantfulltextopen-
crisitem.author.deptFaculty of Computer Science and Engineering-
crisitem.author.deptFaculty of Computer Science and Engineering-
crisitem.author.deptFaculty of Computer Science and Engineering-
crisitem.author.deptFaculty of Computer Science and Engineering-
Appears in Collections:Faculty of Computer Science and Engineering: Journal Articles
Show simple item record

Page view(s)

73
checked on Aug 9, 2024

Download(s)

16
checked on Aug 9, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.