Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12188/16601
DC FieldValueLanguage
dc.contributor.authorJakimovski, Draganen_US
dc.contributor.authorRaportaru, M.C.en_US
dc.contributor.authorBarandovski, Lambeen_US
dc.contributor.authorStojanov, Naceen_US
dc.date.accessioned2022-02-19T19:53:39Z-
dc.date.available2022-02-19T19:53:39Z-
dc.date.issued2018-
dc.identifier.urihttp://hdl.handle.net/20.500.12188/16601-
dc.descriptionEach data file is an ASCI text file with several lines of comments at their beginning with short explanation for columns, units, missing or otherwise unacceptable data, etc. The independent variable is usually put as the last column (as indicated in each file) and is understood by the expression "versus". For example "versus energy" means each line in the file contains results for different physical states and single value of the collisional energy (given number in the indicated column). The name of the file starts with a number, and short explanation of its content for an easy orientation. In the following we list them for convenience of the user file No. 1 : energies of H ion, versus screening parameter for selected states file No. 2 : energies of Li ion, versus screening parameter up to n=7 state file No. 3 : CX sections for E= 1 keV/u, versus screening parameter file No. 4 : CX sections for E= 7 keV/u, versus screening parameter file No. 5 : CX sections for E=50 keV/u, versus screening parameter file No. 6 : CX sections for D=2.5au screening parameter, versus energy file No. 7 : CX sections for D= 4 au screening parameter, versus energy file No. 8 : CX sections for D= 6 au screening parameter, versus energy file No. 9 : CX sections for D=12 au screening parameter, versus energy file No. 10 : CX sections for pure Coulomb case, versus energy All calculations were performed on HPC at FINKI, Skopje. The authors gratefully acknowledge the support of people in charge of smooth running of the cluster and prof. B. Jakimovski, PhD in particular for helpful advise on many occasions. For further details regarding computations and data itself: dragan.jakimovski@gmail.comen_US
dc.description.abstractThe data files attached to this paper follows the information presented on the corresponding figures. Some of them contains additional data, regarding state energies and charge transfer sections to higher states, which were not presented in the published version of the paper due to page limitations.en_US
dc.language.isoenen_US
dc.subjectelectron captureen_US
dc.subjectcollisionsen_US
dc.subjectplasmaen_US
dc.titleDataset for CROSS SECTIONS FOR ELECTRON CAPTURE IN Li3+ + H(1s) COLLISIONS IN DEBYE PLASMASen_US
dc.typeDataseten_US
dc.relation.publicationhttp://www.rrp.infim.ro/IP/2018/AN203.pdfen_US
item.grantfulltextopen-
item.fulltextWith Fulltext-
crisitem.author.deptFaculty of Natural Sciences and Mathematics-
crisitem.author.deptFaculty of Natural Sciences and Mathematics-
crisitem.author.deptFaculty of Natural Sciences and Mathematics-
Appears in Collections:UKIM 03: Datasets
Files in This Item:
File Description SizeFormat 
1-energies-of-H-versus-screening-D.datenergies of H ion, versus screening parameter for selected states4.43 MBUnknownView/Open
2-energies-of-Li-versus-screening-D.datenergies of Li ion, versus screening parameter up to n=7 state2.15 MBUnknownView/Open
3-cx-sections-for-E-1kev-per-u-versus-D.datCX sections for E= 1 keV/u, versus screening parameter184.48 kBUnknownView/Open
4-cx-sections-for-E-7kev-per-u-versus-D.datCX sections for E= 7 keV/u, versus screening parameter199.09 kBUnknownView/Open
5-cx-sections-for-E-50kev-per-u-versus-D.datCX sections for E=50 keV/u, versus screening parameter192.49 kBUnknownView/Open
6-cx-sections-for-D-2.5-au-versus-E.datCX sections for D=2.5au screening parameter, versus energy66 kBUnknownView/Open
7-cx-sections-for-D-4-au-versus-E.datCX sections for D= 4 au screening parameter, versus energy67.28 kBUnknownView/Open
8-cx-sections-for-D-6-au-versus-E.datCX sections for D= 6 au screening parameter, versus energy67.28 kBUnknownView/Open
9-cx-sections-for-D-12-au-versus-E.datCX sections for D=12 au screening parameter, versus energy67.28 kBUnknownView/Open
10-cx-sections-for-pure-coulomb-case-versus-E.datCX sections for pure Coulomb case, versus energy67.28 kBUnknownView/Open